The Scottish Fire Door Company
    0345 123 4567Request a quote
    0345 123 4567

    Fire door installation

    Supply and fit of certified fire door assemblies for commercial and residential premises across Scotland's Central Belt.

    A fire door is certified as a complete assembly. The leaf, frame, seals, hinges and ironmongery were tested together, and the performance only holds if what goes into the opening matches what was tested.

    That is why installation matters more here than on an ordinary door. A correctly specified door fitted with the wrong hinges, packed badly, or hung in a frame that was never part of the tested set will not perform the way the certificate says.

    What we supply and fit

    Internal fire doors
    Single and double leaf, glazed and unglazed, for corridors, stairwells and compartment walls.
    Flat entrance doors
    Doorsets for individual dwellings in communal residential buildings.
    Commercial doorsets
    Complete factory-assembled sets where the specification calls for them.
    Fire exit and external doors
    Where the opening forms part of the escape route.
    Frames and linings
    Supplied as part of the certified assembly rather than reused from what was there.
    Ironmongery
    Closers, hinges, locks and furniture compatible with the tested assembly.

    Specification

    Rating
    E 30 Sa
    Fire resistance duration
    Short
    Test standard
    BS EN 1634-1

    Building standards in Scotland

    New build, conversion and alteration work in Scotland is governed by the Building (Scotland) Regulations 2004 and the technical handbooks, and generally requires a building warrant from the local authority verifier. That is a different regime from the ongoing duty holder obligations that apply once a building is in use.

    Scottish standards also describe fire door performance differently. Where the trade says FD30 or FD60, the technical handbooks refer to a short or medium fire resistance duration, expressed under the European classification as E 30 Sa or E 60 Sa. They describe the same performance.

    If your project is going through warrant, the door specification needs to match what was approved, not simply what is available.

    Common installation faults

    • Gaps outside tolerance because the frame was not packed and fixed correctly
    • Hinges or ironmongery substituted for components outside the certified set
    • Vision panels or apertures cut on site after the door left the factory
    • Seals omitted, or fitted to the leaf when the tested assembly had them in the frame

    Common questions

    Usually, yes. We can specify doors that match the finish and appearance of what is already there while meeting the required performance.

    Request a fire door installation quote